Description
The BLUELYZER® ST Starter Set perform accurate measurements of O2, CO and temperatures as well as precise calculation of various parameters such as lambda, combustion efficiency (Eta), flue gas loss (qA), dew point and CO2.
Scope of delivery | |
M04438016 | BLUELYZER ST (O2, CO, BLE) |
500265.5 | Flue gas probe 170 mm, with Polyurethan |
500192 | Condensate filter cartridge |
523493 | Power supply unit |
523506 | Charging cable |
521844 | Air sensor |
500214 | Filter set |
511001 | Case |
O2 (oxygen) | |
Measuring range | 0 to 21.0 vol.-% |
Accuracy | ±0.2 vol.-% RDG |
Resolution | 0.1 vol.-% |
Response delay (t90) | < 30 seconds |
CO (carbon monoxide) | |
Measuring range | 0 to 2,000 ppm (max. 6,000 ppm) |
Accuracy | ±5 ppm (< 50 ppm) |
±5% RDG (> 50 ppm) | |
Resolution | 1 ppm |
Response delay (t90) | < 60 seconds |
Flue gas temperature | |
Measuring range | 0 to 1,150 °C |
Accuracy | ±1 °C + 1 digit (< 300 °C) |
±1 % RDG (> 300 °C) | |
Resolution | 0.1 °C |
Response delay (t90) | < 30 seconds |
Ambient air temperature | |
Measuring range | -20 to 200 °C |
Accuracy | ±3 °C + 1 digit (< 0 °C) |
±1 °C + 1 digit (> 0 °C) | |
Resolution | 0.1 °C |
Response delay (t90) | < 30 seconds |
Starter Set
|
Pro Set
|
|
Part no. |
P00007
|
P00008
|
O2, CO (differential) temperature |
✔
|
✔
|
Draft/pressure |
✔
|
|
Aluminium carrying case |
✔
|
✔
|
Flue gas probe Ø 8 - 170 mm / 1.8 m gas / temperature |
✔
|
|
Flue gas probe Ø 8 - 170 mm / 1.8 m gas / pressure / temperature |
✔
|
|
Condensate cartridge |
✔
|
✔
|
5x filter discs and 5x particle filter tabs |
✔
|
✔
|
Ambient air thermocouple |
✔
|
✔
|
Mains unit with USB cable |
✔
|
✔
|
Reviews