Description
Features
- On-board identification and location of the most common mechanical faults (bearings, misalignment, unbalance, looseness) focus maintenance efforts on root cause, reducing unplanned downtime
- Overall vibration level allows you to quickly assess overall machine health directly from the diagnosis screen
- Fault severity scale with four severity levels helps you prioritize maintenance work
- Repair recommendations advise technicians on corrective action
- Detailed diagnostic reports and spectral diagrams help confirm data quality, and narrow down the root cause of failures
- On-board context sensitive help provides real-time tips and guidance to new users
- Flexible machine speed configurations gives the ability to test a broad range of assets including belt drives, gear boxes, and bevel gears
- 2 GB expandable on-board memory provides enough space for your machinery’s data
- Self-test function ensures optimal performance and more time on the job
- Laser tachometer for accurate machine running speed promotes confident diagnoses
- Tri-axial accelerometer reduces measurement time by 2/3 over single axis accelerometers
- Viewer PC Software expands data storage and tracking capacity
Use the Fluke 810 Vibration Tester to
- Troubleshoot problem equipment and understand the root cause of failure
- Survey equipment before and after planned maintenance and confirm the repair
- Commission new equipment and ensure proper installation
- Provide quantifiable proof of equipment condition and drive investment in repair or replacement
- Prioritize and plan repair activities and operate more efficiently
- Anticipate equipment failures before they happen and take control of spare parts inventories
- Train new or less-experienced technicians and build confidence and skill across the team
Diagnostic Specifications | ||
Standard Faults | Unbalance, looseness, misalignment and bearing failures | |
Analysis For | Motors, fans, blowers, belts and chain drives, gearboxes, couplings, centrifugal pumps, piston pumps, sliding vane pumps, propeller pumps, screw pumps, rotary thread/gear/lobe pumps, piston compressors, centrifugal compressors, screw compressors, closed coupled machines, spindles | |
Motor Rotational Speed Range | 200 rpm to 12000 rpm | |
Diagnosis Details | Plain-text diagnosis, fault severity (slight, moderate, serious, extreme), repair details, cited peaks, spectra | |
Electrical Specifications | ||
Ranging | Automatic | |
A/D Converter | 4 channel, 24 bit | |
Usable Bandwidth | 2 Hz to 20 kHz | |
Sampling | 51.2 Hz | |
Digital Signal Processing Functions | Automatically configured anti-alias filter, high-pass filter, decimation, overlapping, windowing, FFT, and averaging | |
Sampling Rate | 2.5 kHz to 50 kHz | |
Dynamic Range | 128 dB | |
Signal To Noise Ratio | 100 dB | |
FFT Resolution | 800 lines | |
Spectral Windows | Hanning | |
Frequency Units | Hz, orders, cpm | |
Amplitude Units | in/sec, mm/sec, VdB (US), VdB* (Europe) | |
Non-volatile Memory | SD micro memory card, 2 GB internal + user accessible slot for additional storage | |
General Specifications | ||
Dimensions (H x D x W) | 18.56 x 7.00 x 26.72 cm (7.30 x 2.76 x 10.52 in) | |
Weight (With Battery) | 1.9 kg (4.2 lb) | |
Display | ¼ VGA, 320 × 240 Color (5.7 inch diagonal) TFT LCD with LED backlight | |
Input/Output Connections | Triaxial sensor connection | 4 pin M12 connector |
Single axis sensor connection | BNC connector | |
Tachometer Connection | Mini DIN 6 pin connector | |
PC Connection | Mini ‘B’ USB (2.0) connector | |
Battery | Battery type | Lithium-ion, 14.8 V, 2.55 Ah |
Battery charging time | Three hours | |
Battery discharge time | Eight hours (under normal conditions) | |
AC Adapter | Input voltage | 100 VAC to 240 VAC |
Input frequency | 50/60 Hz | |
Operating System | WinCE 6.0 Core | |
Language Support | English, French, German, Italian, Japanese, Portuguese, Simplified Chinese, Spanish | |
Warranty | Three-years | |
Environmental Specifications | ||
Operating Temperature | 0°C to 50°C (32°F to 122°F) | |
Storage Temperature | -20°C to 60°C (-4°F to 140°F) | |
Operating Humidity | 10% to 95% RH (non-condensing) | |
Agency Approvals | CHINA RoHS, CSA, CE, C TICK, WEEE | |
Electromagnetic Compatibility | EN 61326-1:2006, EN 61010:1:2001 2nd ed. | |
Sensor Specifications | ||
Sensor Type | Accelerometer | |
Sensitivity | 100 mV/g (±5%, 25°C) | |
Acceleration Range | 80 g peak | |
Amplitude Nonlinearity | 1% | |
Frequency Response | Z | 2 – 7,000 Hz ±3dB |
X, Y | 2 – 5,000 Hz ±3dB | |
Power Requirement (IEPE) | 18 VDC to 30 VDC, 2 mA to 10 mA | |
Bias Output Voltage | 12 VDC | |
Grounding | Case grounded | |
Sensing Element Design | PZT ceramic / shear | |
Case Material | 316L stainless steel | |
Mounting | 10-32 captive socket head screw, 2-pole rare earth magnet (48 lb pull strength) | |
Output Connector | 4-Pin, M12 | |
Mating Connector | M12 – F4D | |
Non-volatile Memory | TEDS 1451.4 compatible | |
Vibration Limit | 500 g peak | |
Shock Limit | 5000 g peak | |
Electromagnetic Sensitivity, Equivalent g | 100 μg/gauss | |
Sealing | Hermetic | |
Temperature Range | -50°C to 120°C (-58°F to 248°F) ±7% | |
Warranty | One-year | |
Tachometer Specifications | ||
Dimensions (D x W) | 2.86 x 12.19 cm (1.125 x 4.80 in) | |
Weight | 96 g (3.4 oz) with cable | |
Power | Powered by 810 Vibration Tester | |
Detection | Laser Diode Class 2 | |
Range | 6.0 to 99,999 rpm | |
Accuracy | 6.0 to 5999.9 rpm | ±0.01% and ±1 digit |
5999.9 to 99999 rpm | ±0.05% and ±1 digit | |
Resolution | 0.1 rpm | |
Effective Range | 1 cm to 100 cm (0.4 in to 39.27 in) | |
Response Time | 1 second (> 60 rpm) | |
Controls | Measure on/off transparent button | |
Interface | 6 Pin Mini DIN | |
Cable Length | 50 cm (19.586 in) | |
Warranty | One-year | |
Tachometer Accessories | Reflective tape | 1.5 x 52.5 cm (0.59 x 20.67 in) |
Viewer PC Software | ||
Minimum Hardware Requirements | 1 GB RAM | |
Operating System Requirements | Windows 7, 8.1, and 10 |