Description
Features
- Source/simulate volts; mA; thermocouples; RTDs; frequency; ohms; and pressure to calibrate transmitters
- Power transmitters during test using loop supply with simultaneous mA measurement
- Measure/source pressure using any of 29 Fluke 700Pxx Pressure Modules
- Create and run automated as-found/as-left procedures to satisfy quality programs or regulations. Record and document results
- Holds up to a full week of downloaded procedures and calibration results.
- Use many features like autostep; custom units; user entered values during test; one-point and two-point switch testing; square root DP flow testing; programmable measurement delay etc.
- Bright white dual display. Read both sourced and measured parameters simultaneously.
- Multi lingual interface
- Rechargeable Li-Ion battery for 10 hour uninterrupted use. Includes gas gauge.
- Handling of fast pulsed RTD transmitters and PLCs; with pulses as short as 1 ms.
- Delivered with DPC/Track Sample software.
Measurement Accuracy | |
Voltage DC | Range/resolution: 100 mV, 3 V, 30 V, 300 V 1 year: 0.02% + 0.005 mV, 0.02% + 0.00005 V, 0.02% + 0.0005 V, 0.05% + 0.05 V 2 years: 0.03% + 0.005 mV, 0.03% + 0.00005 V, 0.03% + 0.0005 V, 0.07% + 0.05 V |
Voltage AC | Range/resolution: 3(40 to 500 Hz)/0.001 V, 30 (40 to 500 Hz)/0.01 V, 300 (40 to 500 Hz)/0.1 V 1 year: 0.5% + 0.002 V, 0.5% + 0.02 V, 0.5% + 0.2 V 2 years: 1.0% + 0.004 V, 1.0% + 0.04 V, 1.0% + 0.2 V |
Current DC | Range/resolution: 30 mA, 110 mA 1 year: 0.01% + 5 µA, 0.01% + 20 µA 2 years: 0.015% + 7 µA, 0.015% + 30 µA |
Resistance | Range/resolution: 10 Ω, 100 Ω, 1 kΩ, 10 kΩ 1 year: 0.05% + 50 mΩ, 0.05% + 50 mΩ, 0.05% + 500 mΩ, 0.1% + 10 Ω 2 years: 0.07% + 70 mΩ, 0.07% + 70 mΩ, 0.07% + 0.5 Ω, 0.15% + 15 Ω |
Frequency | Range/resolution: 1.00 to 110.00 Hz/0.01 Hz, 110.1 to 1100.0 Hz/0.1 Hz, 1.101 to 11.000 kHz/0.001 kHz, 11.01 to 50.00 kHz/0.01 kHz 2 years: 0.05 Hz, 0.5 Hz, 0.005 kHz, 0.05 kHz |
Source Accuracy | |
Voltage DC | Range/resolution: 100 mV, 1 V, 15 V 1 year: 0.01% + 0.005 mV, 0.01% + 0.00005 V, 0.01% + 0.0005 V 2 years: 0.015% + 0.005 mV, 0.015% + 0.0005 V, 0.015% + 0.0005 V |
Current DC | Range/resolution: 22 mA (source), current sink (simulate) 1 year: 0.01% + 0.003 mA, 0.02% + 0.007 mA 2 years: 0.02% + 0.003 mA, 0.04% + 0.007 mA |
Resistance | Range/resolution: 10 Ω, 100 Ω, 1 kΩ, 10 kΩ 1 year: 0.01% + 10 mΩ, 0.01% + 20 mΩ, 0.02% + 0.2 Ω, 0.02% + 3 Ω 2 years: 0.015% + 15 mΩ, 0.015% + 30 mΩ, 0.03% + 0.3 Ω, 0.03% + 5 Ω |
Frequency | Range/resolution: 0.1 to 10.99 Hz, 0.01 to 10.99 Hz, 11.00 to 109.99 Hz, 110.0 to 1099.9 Hz, 1.100 to 21.999 kHz, 22.000 to 50.000 kHz 2 years: 0.01 Hz, 0.01 Hz, 0.1 Hz, 0.1 Hz, 0.002 kHz, 0.005 kHz |
Technical Data | |
Data Log Functions | Measure functions: Voltage, current, resistance, frequency, temperature, pressure Reading rate: 1, 2, 5, 10, 20, 30, or 60 readings/minute Maximum record length: 8000 readings (7980 for 30 or 60 readings/minute) |
Ramp Functions | Source functions: Voltage, current, resistance, frequency, temperature Rate: 4 steps/second Trip detect: Continuity or voltage (continuity detection not available when sourcing current) |
Loop Power Function | Voltage: Selectable, 26 V Accuracy: 10%, 18 V minimum at 22 mA Maximum current: 25 mA, short circuit protected Maximum input voltage: 50 V DC |
Step Functions | Source functions: Voltage, current, resistance, frequency, temperature Manual step: Selectable step, change with arrow buttons Auto-step: Fully programmable for function, start delay, step-value, time per step, repeat |
Environmental Specifications | |
Operating Temperature | 14 to 122°F (-10 to 50°C) |
Storage Temperature | -4 to 140°F (-20 to 60°C) |
Dust/Water Resistance | Meets IP52, IEC 529 |
Operating Altitude | 9842′ (3000 m) above mean sea level |
Mechanical and General Specifications | |
Batteries | Internal Battery Pack Li-ion: 7.2 V, 4400 mAh, 30 Wh |
Battery Life | >8 hours typical |
Battery Replacement | Via snap-shut door without opening calibrator; no tools required |
Side Port Connections | Pressure module connector USB Connector to interface to your PC Connection for optional battery charger/eliminator |
Data Storage Capacity | 1 week of calibration procedures results |
90 Day Specifications | The standard specification interval are 1 and 2 years Typical 90 day measurement and source accuracy can be estimated by dividing the one year “% of reading” or “% of output” specifications by 2. Floor specifications, expressed as “% of full scale” or “counts” or “ohms” remain constant. |
Dimensions | 5.4 x 9.6 x 2.5″ (136 x 245 x 63 mm) |
Weight | 2.7 lbs (1.2 kg) |
Safety Specifications | |
Agency Approvals | CAN/CSA C22.2 No 1010.1-92, ASNI/ISA S82.01-1994, UL3111, and EN610-1:1993 |
Reviews
There are no reviews yet.