Temperature range
Operating: -10 °C to +45 °C (+14 °F to +113 °F)
Storage: -10 °C to +60 °C (+14 °F to +140 °F)
Humidity range
Operating: 0 % to 95 % (32 °F to 95 °F, 0 °C to 35 °C)
RH non-condensing
Storage: 0 % to 95 % (95 °F to 113 °F, 35 °C to 45 °C)
RH non-condensing
Altitude
- Operating: 4,000 m (3,200 m with AC adapter)
- Storage: 12,000 m
Vibration
2 g, 5 Hz to 500 Hz
Shock
1 meter drop test
Safety
IEC 61010-1: Pollution Degree 2
EMC
IEC 61326-1: Controlled Electromagnetic Environment; IEC 61326-2-1
CISPR 11: Group 2, Class A
USA (FCC): 47 CFR 15 Intentional Radiators: This device complies with part 15 of the FCC Rules.
Endtype Support
Single Fiber and MPO: 1×8 (8 fibers), 1×12 (8, 10, or 12 fibers), 1×16 (16 fibers), 2×12 (16, 20, or 24 fibers), 2×16 (32 fibers)
Test Limits
- IEC 61300-3-35 ED. 2 MM
- IEC 61300-3-35 ED. 2 SM APC
Document Only
- Optional automated Pass/Fail Test Time
- Less than 2 seconds per fiber
Camera type
5 Megapixel 1/4-inch CMOS sensor
Field of view
610 µm x 460 µm
Resolution
1 µm
Light source
- LED, >100,000 hr life
- Endface illumination
- Coaxial blue LED
- Port illumination
- White LED
Battery Type
Lithium-ion; 10.8 hour life
Power Adapter
Input: 100 to 240 VAC ±10%, 50/60Hz
Output: 15 VDC, 2 A maximum
Class II
Wireless Transmission*
Output power: <100 mW Frequency ranges: 2.4 GHz (2412 MHz to 2462 MHz)
Dimensions
6.625 in x 5.375 in x 2.125 in (168 mm x 137 mm x 54 mm)
(with no dust cap or adapter tip)
Length with dust cap: 7.5 in (191 mm)
Weight
- 11.5 oz (326 gm)
- (with dust cap and no adapter tip)
Reviews