Description
Input
- Nominal Voltage: 100/110/115/120/127 VAC or 200/208/220/230/240 VAC
- Voltage range: 55-150 VAC ± 3 % or 110- 300 VAC ± 3 % at 50% load
- 80-150 VAC ± 3 % or 160- 300 VAC ± 3 % at 100% load
- Frequency Range: 40Hz-70Hz
- Power Factor @0.99 @ nominal voltage (100% load)
- THDi: @ 5%
Output:
- Output voltage: 100*/110*/115*/120/127 VAC or 200*/208*/220/230/240 VAC
- AC Voltage Regulation (Batt. Mode): ±1%
- Frequency range (Synchronized Range): 47 – 53 Hz or 57- 63Hz
- Frequency range (Batt. Mode): 50Hz ± 0.1 Hz or 60Hz ± 0.1 Hz
- Current Crest Ratio: 3:1
- Harmonic distortion: @ 2% THDi(Linear load), @4 % THD (non-linear Load)
- Transfer time: AC to DC: 0
- Inverter to bypass: 4ms (typical)
- Surge Protection: 600 Joule
- Waveform (Batt.Mode): Pure sine wave
Efficiency:
- Line mode: @ 89% @ battery fully charged
- ECO Mode: @ 96%@ Battery fully charged
- Battery mode: @ 88%
Battery:
- Battery type: 12V/ 9 AH and 12V/ 7 AH
- Numbers: 2 and 3
- Typical recharge time: 3 hours recover to 95% Capacity for internal battery @2A charging current
- Charging current: 100/110/115/120/127 VAC models: default 2A, max.8A adjustable
- Charging voltage: 27.4VDc ± 1%, 41.1VDC ± 1 %
Indicators
- LCD panel: load level, battery level, AC mode, Battery mode, Bypass mode, and fault indicator
Alarm
- Battery mode: sounding every 5 seconds
- Low battery: sounding every 2 seconds
- Overload: sounding every second
- Fault: continuously sounding
Physical
- Dimension (D×W×H) (mm): 397×145×220
- Net Weight (without battery) (kgs): 6.6
- Net weight (w/ built-in battery) (kgs): 11.7 and 13
Environment
- Humidity: 20-95% RH @ 0-40°C (non-condensing)
- Noise level: less than 50dBa @ 1 meter
Management
- Smart RS-232 or USB: Supports window 2000/2003/XP/Vista/2008. Window 7/8/10, Linux and MAC
- Original SNMP: power management from SNMP manager and web browser
Standard
EMC/Safety: EMC EN62040-2 C2 for CE models
Reviews