Description
- Features
- Test voltages to up 10 kV and save time by trending on the spot only with Fluke Connect™
- CAT III 1000 V, CAT IV 600 V safety rating
- Warning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety
- Selectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V
- Measurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall
- Long battery life gives the user over 750 tests between charges
- Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup
- Guard system eliminates the effect of surface leakage current on high-resistance measurements
- Large digital/analog LCD for easy viewing
- Capacitance and leakage current measurement
- Ramp function for breakdown testing
- Resistance measurements up to 2 TΩ
- Timer settings up to 99 minutes for timed tests
- 3-year warranty
Applications
- Building Automation
- Commercial
- Defense
- Military and Aerospace
- HVAC/R
- Industrial
- Maintenance and Repair
- Mining
- Oil and Gas
- Motor Drive and Control
Insulation Resistance | ||
Test voltage (DC) | Range (DC) | Accuracy (± reading) |
250 V | < 250 kΩ 250 kΩ to 5 GΩ 5 GΩ to 50 GΩ > 50 GΩ |
Unspecified 5% 20% Unspecified |
500 V | < 500 kΩ 500 kΩ to 10 GΩ 10 GΩ to 100 GΩ > 100 GΩ |
Unspecified 5% 20% Unspecified |
1000 V | < 1 MΩ 1 MΩ to 20 GΩ 20 GΩ to 200 GΩ > 200 GΩ |
Unspecified 5% 20% Unspecified |
2500 V | < 2.5 MΩ 2.5 MΩ to 50 GΩ 50 GΩ to 500 GΩ > 500 GΩ |
Unspecified 5% 20% Unspecified |
5000 V | < 5 MΩ 5 MΩ to 100 GΩ 100 GΩ to 1 TΩ > 1 TΩ |
Unspecified 5% 20% Unspecified |
10000 V | < 10 MΩ 10 MΩ to 200 GΩ 10 GΩ to 2 TΩ > 2 TΩ |
Unspecified 5% 20% Unspecified |
Leakage Current Measurement | ||
Range | 1 nA to 2 mA | |
Accuracy | ± (5 % + 2 nA) | |
Capacitance Measurement | ||
Range | 0.01 uF to 15.00°F | |
Accuracy | ± (15 % rdg + 0.03°F) | |
Timer | ||
Range | 0 to 99 minutes | |
Accuracy | Resolution Setting: 1 minute Indication: 1 second | |
Live Circuit Warning | ||
Range | Warning Range 30 V to 660 V AC/DC, 50/60 Hz | |
Accuracy | Voltage Accuracy ± (15 % + 2 V) | |
Additional | ||
Bar Graph Range | 0 to 1 TΩ | |
Insulation Test Voltage Accuracy | -0 %, +10 % at 1 mA load current | |
Induced AC Mains Current Rejection | 2 mA maximum | |
Charging Rate for Capacitive Load | 5 seconds per °F | |
Discharge Rate for Capacitive Load | 1.5 s/°F |