Conceptpower DPA 240 UL (ABB)

Conceived for small to mid-sized data centers, ABB’s modular Conceptpower DPA 240 uninterruptible power supply (UPS) fulfill power requirements from 40 kW to 1.2 MW at 415V and provide maximum availability for those who aim for zero downtime as well as a low cost of ownership.

Total vertical and horizontal scalability

The Conceptpower DPA 240 delivers power protection from 40 to 1.2 MW at 415V, both input and output, (one to six modules) in a single cabinet frame. Horizontal scalability is also given, with up to five frames in parallel, to increase total power up to 1.2 MW respectively. This scalability means that there is no need to over-specify the original configuration as power modules can simply be added, as needed, in the future.

True parallel architecture

This advanced UPS design provides the highest degree of protection in critical applications where the load must be fed with quality power. These Conceptpower DPA systems utilize decentralized parallel architecture and ensures the highest level of reliability and availability with true redundancy across modules.

Categories: , Tags: , , , , , ,

Description

 General data  Conceptpower DPA 240
 System power range 40kW–1.2MW
 Nominal power/module 40kW
 Nominal power/frame
(capacity)
240kW
 Output power factor 1.0
 Topology Online double conversion, transformerless, modular,
Decentralized Parallel Architecture
 Parallel configuration Up to 6 modules in one frame / up to 5 frames in parallel
 Cable entry Bottom
 Serviceability Front access only
 Back-feed protection Built-in (standard)
 Connection 5-wires, 3-phase + neutral + ground
Input
Nominal input voltage 3 x 415/240V + neutral + ground
Voltage tolerance < 100% (–15%, +10%),
< 80% (–20%, +10%),
< 60% (–30%, +10%)
Input distortion THDi < 4% at 100% load
Frequency range 50/60Hz ± 5%
Power factor 0.99 @ 100% load
Walk in/soft start  Yes
Output
Nominal input voltage 3 x 415/240V + neutral + ground
Voltage tolerance ± 2.5%
Voltage distortion THDv < 2% in linear mode
Frequency 50/60Hz
Efficiency
Online double conversion Up to 95.6% at nominal load
Environment
Protection rating IP 20
Storage temperature −25° to +70°C
Operating temperature  0° to +40°C
Altitude (above sea level) 1000 m without de-rating
 Batteries
Number of 12V jars/string  42 – 50 jars
Types  VRLA, NiCd
Battery charger  Decentralized charger in each module set
Communications
User interface Graphical touch screen (one per frame as standard)
Decentralized LCD + mimic diagram (one per module as standard)
Communication ports USB, RS-232, voltage-free contacts, SNMP (optional)
Customer interface Remote shutdown, gen-set interface, external bypass contact
Compliancy
Safety UL 1778 5th edition, CSA C22.2 No. 107.3-14 Third Edition
 EMC IEC/EN 62040-2 C3
Manufacturing ISO 9001:2008
 Weight, Dimensions
Weight
(System with 6 modules)
 1517 lbs. (688 kg)
Dimensions WxHxD  31.16″ x 77.76″ x 35.17″ (791 x 893 x 1975.5 mm)

Note: Please refer to ABB Conceptpower DPA 240 technical documents for configurations, features, recommendations and guidelines.