Description
Standard & EU Directives Conformance
• 250MHz shielded connectors according to IEC 60603-7-5
• 250MHz shielded connectors according to EN 60603-7-5
• Category 6 connecting hardware according to ANSI/TIA-568.2-D
• UL94 V-0 flame test
• EU Directive 2011/65/EU (RoHS-2)
Mechanical & Electrical Properties
Orientation: 180º
Termination blocks: TL IDC
Insertion/withdrawal: 750 cycles
Cable re-termination: 20 terminations
Operating temperature: -20 to +60C at 5-95% RH (non condensing)
Ampacity: 1.5 A max.
Contact resistance: 20 mOhm max.
DC resistance: 0.1 Ohm max.
Voltage rating: 72 Vdc max.
Insulation resistance: 500 MegaOhm min. @500 Vdc
Angled jacks are compatible only with 24-port 2-row 1U panels
Reviews